This site is intended for healthcare professionals
FDA Hero  Banner - Multi-coloured pills and tablets
FDA Drug information

Fludeoxyglucose F 18

Read time: 4 mins
Marketing start date: 29 Apr 2024

Summary of product characteristics


Adverse Reactions

6 ADVERSE REACTIONS Hypersensitivity reactions with pruritus, edema and rash have been reported in the post-marketing setting. Have emergency resuscitation equipment and personnel immediately available. Hypersensitivity reactions have occurred; have emergency resuscitation equipment and personnel immediately available ( 6 ). To report SUSPECTED ADVERSE REACTIONS, contact Decatur Memorial Hospital at 800-826-2827 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch.

Contraindications

4 CONTRAINDICATIONS None. None ( 4 ).

Description

11 DESCRIPTION 11.1 Chemical Characteristics Fludeoxyglucose F18 Injection, USP is a positron emitting radiopharmaceutical that is used for diagnostic purposes in conjunction with positron emission tomography (PET) imaging. The active ingredient 2-deoxy-2-[ 18 F]fluoro-D-glucose has the molecular formula of C 6 H 11 18 FO 5 with a molecular weight of 181.26, and has the following chemical structure: Fludeoxyglucose F 18 Injection, USP is provided as a ready to use sterile, pyrogen free, clear, colorless citrate buffered solution. Each mL contains between 0.740 GBq—11.1 GBq (20.0 mCi—300 mCi) of 2-deoxy-2-[ 18 F]fluoro-D-glucose at the EOS, 4.5 mg of sodium chloride in citrate buffer. The pH of the solution is between 4.5 and 7.5. The solution is packaged in a multiple-dose glass vial and does not contain any preservative. Chemical Structure 11.2 Physical Characteristics Fluorine F18 has a physical half-life of 109.7 minutes and decays to Oxygen O 18 (stable) by positron decay. The principal photons useful for imaging are the dual 511 keV “annihilation” gamma photons that are produced and emitted simultaneously in opposite directions when the positron interacts with an electron ( Table 2 ). Table 2. Principal Radiation Emission Data for Fluorine F18 *Produced by positron annihilation From: Kocher, D.C. Radioactive Decay Tables DOE/TIC-I 1026, 89 (1981) Radiation/Emission % Per Disintegration Mean Energy Positron(β+) 96.73 249.8 keV Gamma (±)* 193.46 511.0 keV The specific gamma ray constant (point source air kerma coefficient) for fluorine F18 is 5.7 R/hr/mCi (1.35 x 10 ‑6 Gy/hr/kBq) at 1 cm. The half-value layer (HVL) for the 511 keV photons is 4 mm lead (Pb). The range of attenuation coefficients for this radionuclide as a function of lead shield thickness is shown in Table 3 . For example, the interposition of an 8 mm thickness of Pb, with a coefficient of attenuation of 0.25, will decrease the external radiation by 75%. Table 3. Radiation Attenuation of 511 keV Photons by lead (Pb) shielding Shield Thickness (Pb) mm Coefficient of Attentuation 0 0.00 4 0.50 8 0.25 13 0.10 26 0.01 39 0.001 52 0.0001 For use in correcting for physical decay of this radionuclide, the fractions remaining at selected intervals after calibration are shown in Table 4 . Table 4. Physical Decay Chart for Fluorine F18 * calibration time Minutes Fraction Remaining 0* 1.000 15 0.909 30 0.826 60 0.683 110 0.500 220 0.250

Dosage And Administration

2 DOSAGE AND ADMINISTRATION Fludeoxyglucose F18 Injection emits radiation. Use procedures to minimize radiation exposure. Calculate the final dose from the end of synthesis (EOS) time using proper radioactive decay factors. Assay the final dose in a properly calibrated dose calibrator before administration to the patient [see Description ( 11.2 )] . Fludeoxyglucose F18 Injection emits radiation. Use procedures to minimize radiation exposure. Screen for blood glucose abnormalities. • In the oncology and neurology settings, instruct patients to fast for 4 – 6 hours prior to the drug’s injection. Consider medical therapy and laboratory testing to assure at least two days of normoglycemia prior to the drug’s administration ( 5.2 ). • In the cardiology setting, administration of glucose-containing food or liquids (e.g., 50–75 grams) prior to the drug’s injection facilitates localization of cardiac ischemia ( 2.3 ). Aseptically withdraw Fludeoxyglucose F 18 Injection from its container and administer by intravenous injection ( 2 ).The recommended dose: • For adults is 5 mCi–10 mCi (185 MBq–370 MBq), in all indicated clinical settings ( 2.1 ). • For pediatric patients is 2.6 mCi (96.2 MBq) in the neurology setting ( 2.2 ). Initiate imaging within 40 minutes following drug injection; acquire static emission images 30–100 minutes from time of injection ( 2 ). 2.1 Recommended Dose for Adults Within the oncology, cardiology and neurology settings, the recommended dose for adults is 5 mCi–10 mCi (185 MBq–370 MBq) as an intravenous injection. 2.2 Recommended Dose for Pediatric Patients Within the neurology setting, the recommended dose for pediatric patients is 2.6 mCi, as an intravenous injection. The optimal dose adjustment on the basis of body size or weight has not been determined [see Use in Special Populations ( 8.4 )] . 2.3 Patient Preparation • To minimize the radiation absorbed dose to the bladder, encourage adequate hydration. Encourage the patient to drink water or other fluids (as tolerated) in the 4 hours before their PET study. • Encourage the patient to void as soon as the imaging study is completed and as often as possible thereafter for at least one hour. • Screen patients for clinically significant blood glucose abnormalities by obtaining a history and/or laboratory tests [see Warnings and Precautions ( 5.2 )] . Prior to Fludeoxyglucose F18 PET imaging in the oncology and neurology settings, instruct patient to fast for 4–6 hours prior to the drug’s injection. • In the cardiology setting, administration of glucose-containing food or liquids (e.g., 50–75 grams) prior to Fludeoxyglucose F18 Injection facilitates localization of cardiac ischemia. 2.4 Radiation Dosimetry The estimated human absorbed radiation doses (rem/mCi) to a newborn (3.4 kg), 1-year old (9.8 kg), 5-year old (19 kg), 10-year old (32 kg), 15-year old (57 kg), and adult (70 kg) from intravenous administration of Fludeoxyglucose F18 Injection are shown in Table 1 . These estimates were calculated based on human data 1 and using the data published by the International Commission on Radiological Protection 2 for Fludeoxyglucose 18F. The dosimetry data show that there are slight variations in absorbed radiation dose for various organs in each of the age groups. These dissimilarities in absorbed radiation dose are due to developmental age variations (e.g., organ size, location, and overall metabolic rate for each age group). The identified critical organs (in descending order) across all age groups evaluated are the urinary bladder, heart, pancreas, spleen, and lungs. Table 1. Estimated Absorbed Radiation Doses (rem/mCi) After Intravenous Administration of Fludeoxyglucose F18 Injection a a MIRDOSE 2 software was used to calculate the radiation absorbed dose. b The dynamic bladder model with a uniform voiding frequency of 1.5 hours was used. *LLI = lower large intestine; **ULI = upper large intestine. Organ Newborn (3.4kg) 1-year old (9.8 kg) 5-year old (19kg) 10-year old (32 kg) 15-year old (57 kg) Adult (70 kg) Bladder Wall b 4.3 1.7 0.93 0.60 0.40 0.32 Heart Wall 2.4 1.2 0.70 0.44 0.29 0.22 Pancreas 2.2 0.68 0.33 0.25 0.13 0.096 Spleen 2.2 0.84 0.46 0.29 0.19 0.14 Lungs 0.96 0.38 0.20 0.13 0.092 0.064 Kidneys 0.81 0.34 0.19 0.13 0.089 0.074 Ovaries 0.80 0.8 0.19 0.11 0.058 0.053 Uterus 0.79 0.35 0.19 0.12 0.076 0.062 LLI Wall* 0.69 0.28 0.15 0.097 0.060 0.051 Liver 0.69 0.31 0.17 0.11 0.076 0.058 Gallbladder Wall 0.69 0.26 0.14 0.093 0.059 0.049 Small Intestine 0.68 0.29 0.15 0.096 0.060 0.047 ULI Wall** 0.67 0.27 0.15 0.090 0.057 0.046 Stomach Wall 0.65 0.27 0.14 0.089 0.057 0.047 Adrenals 0.65 0.28 0.15 0.095 0.061 0.048 Testes 0.64 0.27 0.14 0.085 0.052 0.041 Red Marrow 0.62 0.26 0.14 0.089 0.057 0.047 Thymus 0.61 0.26 0.14 0.086 0.056 0.044 Thyroid 0.61 0.26 0.13 0.080 0.049 0.039 Muscle 0.58 0.25 0.13 0.078 0.049 0.039 Bone Surface 0.57 0.24 0.12 0.079 0.052 0.041 Breast 0.54 0.22 0.11 0.068 0.043 0.034 Skin 0.49 0.20 0.10 0.060 0.037 0.030 Brain 0.29 0.13 0.09 0.078 0.072 0.070 Other Tissues 0.59 0.25 0.13 0.083 0.052 0.042 2.5 Radiation Safety - Drug Handling • Use waterproof gloves, effective radiation shielding, and appropriate safety measures when handling Fludeoxyglucose F18 Injection to avoid unnecessary radiation exposure to the patient, occupational workers, clinical personnel and other persons. • Radiopharmaceuticals should be used by or under the control of physicians who are qualified by specific training and experience in the safe use and handling of radionuclides, and whose experience and training have been approved by the appropriate governmental agency authorized to license the use of radionuclides. • Calculate the final dose from the end of synthesis (EOS) time using proper radioactive decay factors. Assay the final dose in a Properly calibrated dose calibrator before administration to the patient [see Description ( 11.2 )] . • The dose of Fludeoxyglucose F18 used in a given patient should be minimized consistent with the objectives of the procedure, and the nature of the radiation detection devices employed. 2.6 Drug Preparation and Administration • Calculate the necessary volume to administer based on calibration time and dose. • Aseptically withdraw Fludeoxyglucose F18 Injection from its container. • Inspect Fludeoxyglucose F18 Injection visually for particulate matter and discoloration before administration, whenever solution and container permit. • Do not administer the drug if it contains particulate matter or discoloration; dispose of these unacceptable or unused preparations in a safe manner, in compliance with applicable regulations. • Use Fludeoxyglucose F18 Injection within 12 hours from the EOS. 2.7 Imaging Guidelines • Initiate imaging within 40 minutes following Fludeoxyglucose F18 Injection administration. • Acquire static emission images 30–100 minutes from the time of injection.

Indications And Usage

1 INDICATIONS AND USAGE Fludeoxyglucose F18 Injection, USP is indicated for positron emission tomography (PET) imaging in the following settings: Fludeoxyglucose F18 Injection, USP is indicated for positron emission tomography (PET) imaging in the following settings: • Oncology: For assessment of abnormal glucose metabolism to assist in the evaluation of malignancy in patients with known or suspected abnormalities found by other testing modalities, or in patients with an existing diagnosis of cancer. • Cardiology: For the identification of left ventricular myocardium with residual glucose metabolism and reversible loss of systolic function in patients with coronary artery disease and left ventricular dysfunction, when used together with myocardial perfusion imaging. • Neurology: For the identification of regions of abnormal glucose metabolism associated with foci of epileptic seizures ( 1 ). 1.1 Oncology For assessment of abnormal glucose metabolism to assist in the evaluation of malignancy in patients with known or suspected abnormalities found by other testing modalities, or in patients with an existing diagnosis of cancer. 1.2 Cardiology For the identification of left ventricular myocardium with residual glucose metabolism and reversible loss of systolic function in patients with coronary artery disease and left ventricular dysfunction, when used together with myocardial perfusion imaging. 1.3 Neurology For the identification of regions of abnormal glucose metabolism associated with foci of epileptic seizures.

Drug Interactions

7 DRUG INTERACTIONS The interaction of Fludeoxyglucose F18 Injection with other drugs taken by patients undergoing PET imaging has not been studied.

Clinical Pharmacology

12 CLINICAL PHARMACOLOGY 12.1 Mechanism of Action Fludeoxyglucose F 18 is a glucose analog that concentrates in cells that rely upon glucose as an energy source, or in cells whose dependence on glucose increases under pathophysiological conditions. Fludeoxyglucose F18 is transported through the cell membrane by facilitative glucose transporter proteins and is phosphorylated within the cell to [ 18 F] FDG-6-phosphate by the enzyme hexokinase. Once phosphorylated it cannot exit until it is dephosphorylated by glucose-6-phosphatase. Therefore, within a given tissue or pathophysiological process, the retention and clearance of Fludeoxyglucose F 18 reflect a balance involving glucose transporter, hexokinase and glucose-6-phosphatase activities. Fludeoxyglucose F18 is used to assess glucose metabolism. In comparison to background activity of the specific organ or tissue type, regions of decreased or absent uptake of Fludeoxyglucose F 18 reflect the decrease or absence of glucose metabolism. Regions of increased uptake of Fludeoxyglucose F18 reflect greater than normal rates of glucose metabolism. 12.2 Pharmacodynamics Fludeoxyglucose F18 Injection is rapidly distributed to all organs of the body after intravenous administration. After background clearance of Fludeoxyglucose F18 Injection, optimal PET imaging is generally achieved between 30 to 40 minutes after administration. In cancer, the cells are generally characterized by enhanced glucose metabolism partially due to (1) an increase in activity of glucose transporters, (2) an increased rate of phosphorylation activity, (3) a reduction of phosphatase activity or, (4) a dynamic alteration in the balance among all these processes. However, glucose metabolism of cancer as reflected by Fludeoxyglucose F 18 accumulation shows considerable variability. Depending on tumor type, stage, and location, Fludeoxyglucose F18 accumulation may be increased, normal, or decreased. Also, inflammatory cells can have the same variability of uptake of Fludeoxyglucose F18. In the heart, under normal aerobic conditions, the myocardium meets the bulk of its energy requirements by oxidizing free fatty acids. Most of the exogenous glucose taken up by the myocyte is converted into glycogen. However, under ischemic conditions, the oxidation of free fatty acids decreases, exogenous glucose becomes the preferred myocardial substrate, glycolysis is stimulated, and glucose taken up by the myocyte is metabolized immediately instead of being converted into glycogen. Under these conditions, phosphorylated Fludeoxyglucose F18 accumulates in the myocyte and can be detected with PET imaging. In the brain, cells normally rely on aerobic metabolism. In epilepsy, the glucose metabolism varies. Generally, during a seizure, glucose metabolism increases. Interictally, the seizure focus tends to be hypometabolic. 12.3 Pharmacokinetics Distribution : In four healthy male volunteers, receiving an intravenous administration of 30 seconds in duration, the arterial blood level profile for Fludeoxyglucose F 18 decayed triexponentially. The effective half-life ranges of the three phases were 0.2-0.3 minutes, 10-13 minutes with a mean and standard deviation (STD) of 12 (±) 1 min, and 80-95 minutes with a mean and STD of 88 (±) 4 min. Plasma protein binding of Fludeoxyglucose F18 has not been studied. Metabolism : Fludeoxyglucose F 18 is transported into cells and phosphorylated to [ 18 F]‑FDG-6- phosphate at a rate proportional to the rate of glucose utilization within that tissue. [F18]-FDG-6-phosphate presumably is metabolized to 2-deoxy-2-[F18]fluoro-6‑phospho-D-mannose ([F18]FDM-6-phosphate). Fludeoxyglucose F18 Injection may contain several impurities (e.g., 2-deoxy-2-chloro‑D-glucose (ClDG)). Biodistribution and metabolism of ClDG are presumed to be similar to Fludeoxyglucose F 18 and would be expected to result in intracellular formation of 2‑deoxy-2-chloro-6-phospho-D-glucose (ClDG-6-phosphate) and 2-deoxy-2-chloro-6‑phospho-D-mannose (ClDM-6-phosphate). The phosphorylated deoxyglucose compounds are dephosphorylated and the resulting compounds (FDG, FDM, ClDG, and ClDM) presumably leave cells by passive diffusion. Fludeoxyglucose F18 and related compounds are cleared from non-cardiac tissues within 3 to 24 hours after administration. Clearance from the cardiac tissue may require more than 96 hours. Fludeoxyglucose F18 that is not involved in glucose metabolism in any tissue is then excreted in the urine. Elimination : Fludeoxyglucose F18 is cleared from most tissues within 24 hours and can be eliminated from the body unchanged in the urine. Within 33 minutes, a mean of 3.9% of the administrated radioactive dose was measured in the urine. The amount of radiation exposure of the urinary bladder at two hours post-administration suggests that 20.6% (mean) of the radioactive dose was present in the bladder. Special Populations : The pharmacokinetics of Fludeoxyglucose F18 Injection have not been studied in renally-impaired, hepatically impaired or pediatric patients. Fludeoxyglucose F18 is eliminated through the renal system. Avoid excessive radiation exposure to this organ system and adjacent tissues. The effects of fasting, varying blood sugar levels, conditions of glucose intolerance, and diabetes mellitus on Fludeoxyglucose F18 distribution in humans have not been ascertained [see Warnings and Precautions ( 5.2 )] .

Mechanism Of Action

12.1 Mechanism of Action Fludeoxyglucose F 18 is a glucose analog that concentrates in cells that rely upon glucose as an energy source, or in cells whose dependence on glucose increases under pathophysiological conditions. Fludeoxyglucose F18 is transported through the cell membrane by facilitative glucose transporter proteins and is phosphorylated within the cell to [ 18 F] FDG-6-phosphate by the enzyme hexokinase. Once phosphorylated it cannot exit until it is dephosphorylated by glucose-6-phosphatase. Therefore, within a given tissue or pathophysiological process, the retention and clearance of Fludeoxyglucose F 18 reflect a balance involving glucose transporter, hexokinase and glucose-6-phosphatase activities. Fludeoxyglucose F18 is used to assess glucose metabolism. In comparison to background activity of the specific organ or tissue type, regions of decreased or absent uptake of Fludeoxyglucose F 18 reflect the decrease or absence of glucose metabolism. Regions of increased uptake of Fludeoxyglucose F18 reflect greater than normal rates of glucose metabolism.

Pharmacodynamics

12.2 Pharmacodynamics Fludeoxyglucose F18 Injection is rapidly distributed to all organs of the body after intravenous administration. After background clearance of Fludeoxyglucose F18 Injection, optimal PET imaging is generally achieved between 30 to 40 minutes after administration. In cancer, the cells are generally characterized by enhanced glucose metabolism partially due to (1) an increase in activity of glucose transporters, (2) an increased rate of phosphorylation activity, (3) a reduction of phosphatase activity or, (4) a dynamic alteration in the balance among all these processes. However, glucose metabolism of cancer as reflected by Fludeoxyglucose F 18 accumulation shows considerable variability. Depending on tumor type, stage, and location, Fludeoxyglucose F18 accumulation may be increased, normal, or decreased. Also, inflammatory cells can have the same variability of uptake of Fludeoxyglucose F18. In the heart, under normal aerobic conditions, the myocardium meets the bulk of its energy requirements by oxidizing free fatty acids. Most of the exogenous glucose taken up by the myocyte is converted into glycogen. However, under ischemic conditions, the oxidation of free fatty acids decreases, exogenous glucose becomes the preferred myocardial substrate, glycolysis is stimulated, and glucose taken up by the myocyte is metabolized immediately instead of being converted into glycogen. Under these conditions, phosphorylated Fludeoxyglucose F18 accumulates in the myocyte and can be detected with PET imaging. In the brain, cells normally rely on aerobic metabolism. In epilepsy, the glucose metabolism varies. Generally, during a seizure, glucose metabolism increases. Interictally, the seizure focus tends to be hypometabolic.

Pharmacokinetics

12.3 Pharmacokinetics Distribution : In four healthy male volunteers, receiving an intravenous administration of 30 seconds in duration, the arterial blood level profile for Fludeoxyglucose F 18 decayed triexponentially. The effective half-life ranges of the three phases were 0.2-0.3 minutes, 10-13 minutes with a mean and standard deviation (STD) of 12 (±) 1 min, and 80-95 minutes with a mean and STD of 88 (±) 4 min. Plasma protein binding of Fludeoxyglucose F18 has not been studied. Metabolism : Fludeoxyglucose F 18 is transported into cells and phosphorylated to [ 18 F]‑FDG-6- phosphate at a rate proportional to the rate of glucose utilization within that tissue. [F18]-FDG-6-phosphate presumably is metabolized to 2-deoxy-2-[F18]fluoro-6‑phospho-D-mannose ([F18]FDM-6-phosphate). Fludeoxyglucose F18 Injection may contain several impurities (e.g., 2-deoxy-2-chloro‑D-glucose (ClDG)). Biodistribution and metabolism of ClDG are presumed to be similar to Fludeoxyglucose F 18 and would be expected to result in intracellular formation of 2‑deoxy-2-chloro-6-phospho-D-glucose (ClDG-6-phosphate) and 2-deoxy-2-chloro-6‑phospho-D-mannose (ClDM-6-phosphate). The phosphorylated deoxyglucose compounds are dephosphorylated and the resulting compounds (FDG, FDM, ClDG, and ClDM) presumably leave cells by passive diffusion. Fludeoxyglucose F18 and related compounds are cleared from non-cardiac tissues within 3 to 24 hours after administration. Clearance from the cardiac tissue may require more than 96 hours. Fludeoxyglucose F18 that is not involved in glucose metabolism in any tissue is then excreted in the urine. Elimination : Fludeoxyglucose F18 is cleared from most tissues within 24 hours and can be eliminated from the body unchanged in the urine. Within 33 minutes, a mean of 3.9% of the administrated radioactive dose was measured in the urine. The amount of radiation exposure of the urinary bladder at two hours post-administration suggests that 20.6% (mean) of the radioactive dose was present in the bladder. Special Populations : The pharmacokinetics of Fludeoxyglucose F18 Injection have not been studied in renally-impaired, hepatically impaired or pediatric patients. Fludeoxyglucose F18 is eliminated through the renal system. Avoid excessive radiation exposure to this organ system and adjacent tissues. The effects of fasting, varying blood sugar levels, conditions of glucose intolerance, and diabetes mellitus on Fludeoxyglucose F18 distribution in humans have not been ascertained [see Warnings and Precautions ( 5.2 )] .

Effective Time

20201117

Version

2

Description Table

Table 2. Principal Radiation Emission Data for Fluorine F18
*Produced by positron annihilation From: Kocher, D.C. Radioactive Decay Tables DOE/TIC-I 1026, 89 (1981)

Radiation/Emission

% Per Disintegration

Mean Energy

Positron(β+)

96.73

249.8 keV

Gamma (±)*

193.46

511.0 keV

Dosage And Administration Table

Table 1. Estimated Absorbed Radiation Doses (rem/mCi) After Intravenous Administration of Fludeoxyglucose F18 Injectiona
a MIRDOSE 2 software was used to calculate the radiation absorbed dose. b The dynamic bladder model with a uniform voiding frequency of 1.5 hours was used. *LLI = lower large intestine; **ULI = upper large intestine.

Organ

Newborn (3.4kg)

1-year old (9.8 kg)

5-year old (19kg)

10-year old (32 kg)

15-year old (57 kg)

Adult (70 kg)

Bladder Wallb

4.3

1.7

0.93

0.60

0.40

0.32

Heart Wall

2.4

1.2

0.70

0.44

0.29

0.22

Pancreas

2.2

0.68

0.33

0.25

0.13

0.096

Spleen

2.2

0.84

0.46

0.29

0.19

0.14

Lungs

0.96

0.38

0.20

0.13

0.092

0.064

Kidneys

0.81

0.34

0.19

0.13

0.089

0.074

Ovaries

0.80

0.8

0.19

0.11

0.058

0.053

Uterus

0.79

0.35

0.19

0.12

0.076

0.062

LLI Wall*

0.69

0.28

0.15

0.097

0.060

0.051

Liver

0.69

0.31

0.17

0.11

0.076

0.058

Gallbladder Wall

0.69

0.26

0.14

0.093

0.059

0.049

Small Intestine

0.68

0.29

0.15

0.096

0.060

0.047

ULI Wall**

0.67

0.27

0.15

0.090

0.057

0.046

Stomach Wall

0.65

0.27

0.14

0.089

0.057

0.047

Adrenals

0.65

0.28

0.15

0.095

0.061

0.048

Testes

0.64

0.27

0.14

0.085

0.052

0.041

Red Marrow

0.62

0.26

0.14

0.089

0.057

0.047

Thymus

0.61

0.26

0.14

0.086

0.056

0.044

Thyroid

0.61

0.26

0.13

0.080

0.049

0.039

Muscle

0.58

0.25

0.13

0.078

0.049

0.039

Bone Surface

0.57

0.24

0.12

0.079

0.052

0.041

Breast

0.54

0.22

0.11

0.068

0.043

0.034

Skin

0.49

0.20

0.10

0.060

0.037

0.030

Brain

0.29

0.13

0.09

0.078

0.072

0.070

Other Tissues

0.59

0.25

0.13

0.083

0.052

0.042

Dosage Forms And Strengths

3 DOSAGE FORMS AND STRENGTHS Multiple-dose glass vial containing 0.74 GBq—11.1 GBq (20 mCi/mL—300 mCi/mL) of Fludeoxyglucose F18 Injection and 4.5 mg of sodium chloride in citrate buffer (approximately 20 mL volume) for intravenous administration. Multiple-dose glass vial containing 0.74 GBq –11.1 GBq (20 mCi/mL–300 mCi/mL) of Fludeoxyglucose F18 Injection and 4.5 mg of sodium chloride in citrate buffer (approximately 20 mL volume), for intravenous administration ( 3 ).

Spl Product Data Elements

Fludeoxyglucose F 18 Fludeoxyglucose F 18 FLUDEOXYGLUCOSE F-18 FLUDEOXYGLUCOSE F-18 SODIUM CHLORIDE SODIUM CITRATE, UNSPECIFIED FORM

Carcinogenesis And Mutagenesis And Impairment Of Fertility

13.1 Carcinogenesis, Mutagenesis, Impairment of Fertility Animal studies have not been performed to evaluate the Fludeoxyglucose F18 Injection carcinogenic potential, mutagenic potential or effects on fertility.

Nonclinical Toxicology

13 NONCLINICAL TOXICOLOGY 13.1 Carcinogenesis, Mutagenesis, Impairment of Fertility Animal studies have not been performed to evaluate the Fludeoxyglucose F18 Injection carcinogenic potential, mutagenic potential or effects on fertility.

Application Number

ANDA204463

Brand Name

Fludeoxyglucose F 18

Generic Name

Fludeoxyglucose F 18

Product Ndc

73410-003

Product Type

HUMAN PRESCRIPTION DRUG

Route

INTRAVENOUS

Package Label Principal Display Panel

PRINCIPAL DISPLAY PANEL - Vial Label Vial Label Fludeoxyglucose F 18 Injection, USP For Intravenous Use 20 mCi/mL to 300 mCi/mL @ EOS* Lot #: Rx Only NDC# 73410-003-01 Sterile, Non-pyrogenic. Contains 0.74 GBq to 11.1 GBq (20 mCi/mL to 300 mCi/mL) @ EOS* of no-carrier added Fludeoxyglucose F18 in 4.5mg NaCl in Citrate Buffer. Multi-Dose Vial Diagnostic - For Intravenous Use Only. Store @ 25°C (77°F); See Insert. Store upright in shielded container. Aseptically withdraw/handle doses. *EOS - End of Synthesis. Expires 12 hours after EOS. Calculate correct dosage from date and time of calibration. Do not use if cloudy or contains particulate matter. (F18) Half-life = 109.7 minutes. Manufactured by: Decatur Memorial Hospital Decatur, IL 62526 Caution: Radioactive Material Principal Display Panel - Vial Label

Spl Unclassified Section

Manufactured by: Decatur Memorial Hospital Center for Advanced Molecular Medicine 2300 North Edward Street, Suite 100 Decatur, Illinois 62526 Distributed by: Decatur Memorial Hospital Center for Advanced Molecular Medicine 2300 North Edward Street, Suite 100 Decatur, Illinois 62526

Information For Patients

17 PATIENT COUNSELING INFORMATION Instruct patients in procedures that increase renal clearance of radioactivity. Encourage patients to: • Drink water or other fluids (as tolerated) in the 4 hours before their PET study. • Void as soon as the imaging study is completed and as often as possible thereafter for at least one hour. Pregnancy: Advise pregnant women of the risk of fetal exposure to radiation with Fludeoxyglucose F 18 Injection [see Use in Specific Populations ( 8.1 )] . Lactation: Advise lactating women that exposure to Fludeoxyglucose F 18 Injection through breast milk can be minimized by pumping and discarding breast milk and avoiding close (breast) contact with the infant for 9 hours after Fludeoxyglucose F 18 Injection [see Use in Specific Populations ( 8.2 )] .

Clinical Studies

14 CLINICAL STUDIES 14.1 Oncology The efficacy of Fludeoxyglucose F18 Injection in positron emission tomography cancer imaging was demonstrated in 16 independent studies. These studies prospectively evaluated the use of Fludeoxyglucose F18 in patients with suspected or known malignancies, including non-small cell lung cancer, colo-rectal, pancreatic, breast, thyroid, melanoma, Hodgkin's and non-Hodgkin's lymphoma, and various types of metastatic cancers to lung, liver, bone, and axillary nodes. All these studies had at least 50 patients and used pathology as a standard of truth. The Fludeoxyglucose F18 Injection doses in the studies ranged from 200 MBq to 740 MBq with a median and mean dose of 370 MBq. In the studies, the diagnostic performance of Fludeoxyglucose F18 Injection varied with the type of cancer, size of cancer, and other clinical conditions. False negative and false positive scans were observed. Negative Fludeoxyglucose F18 Injection PET scans do not exclude the diagnosis of cancer. Positive Fludeoxyglucose F18 Injection PET scans cannot replace pathology to establish a diagnosis of cancer. Non-malignant conditions such as fungal infections, inflammatory processes and benign tumors have patterns of increased glucose metabolism that may give rise to false-positive scans. The efficacy of Fludeoxyglucose F18 Injection PET imaging in cancer screening was not studied. 14.2 Cardiology The efficacy of Fludeoxyglucose F 18 Injection for cardiac use was demonstrated in ten independent, prospective studies of patients with coronary artery disease and chronic left ventricular systolic dysfunction who were scheduled to undergo coronary revascularization. Before revascularization, patients underwent PET imaging with Fludeoxyglucose F18 Injection, (74 MBq—370 MBq, 2 mCi—10 mCi) and perfusion imaging with other diagnostic radiopharmaceuticals. Doses of Fludeoxyglucose F18 Injection ranged from 74 MBq—370 MBq (2 mCi—10 mCi). Segmental, left ventricular, wall-motion assessments of asynergic areas made before revascularization were compared in a blinded manner to assessments made after successful revascularization to identify myocardial segments with functional recovery. Left ventricular myocardial segments were predicted to have reversible loss of systolic function if they showed Fludeoxyglucose F18 accumulation and reduced perfusion (i.e., flow-metabolism mismatch). Conversely, myocardial segments were predicted to have irreversible loss of systolic function if they showed reductions in both Fludeoxyglucose F18 accumulation and perfusion (i.e., matched defects). Findings of flow-metabolism mismatch in a myocardial segment may suggest that successful revascularization will restore myocardial function in that segment. However, false-positive tests occur regularly, and the decision to have a patient undergo revascularization should not be based on PET findings alone. Similarly, findings of a matched defect in a myocardial segment may suggest that myocardial function will not recover in that segment, even if it is successfully revascularized. However, false-negative tests occur regularly, and the decision to recommend against coronary revascularization, or to recommend a cardiac transplant, should not be based on PET findings alone. The reversibility of segmental dysfunction as predicted with Fludeoxyglucose F18 PET imaging depends on successful coronary revascularization. Therefore, in patients with a low likelihood of successful revascularization, the diagnostic usefulness of PET imaging with Fludeoxyglucose F18 Injection is more limited. 14.3 Neurology In a prospective, open label trial, Fludeoxyglucose F18 Injection was evaluated in 86 patients with epilepsy. Each patient received a dose of Fludeoxyglucose F18 Injection in the range of 185 MBq—370 MBq (5 mCi—10 mCi). The mean age was 16.4 years (range: 4 months - 58 years; of these, 42 patients were less than 12 years and 16 patients were less than 2 years old). Patients had a known diagnosis of complex partial epilepsy and were under evaluation for surgical treatment of their seizure disorder. Seizure foci had been previously identified on ictal EEGs and sphenoidal EEGs. Fludeoxyglucose F18 Injection PET imaging confirmed previous diagnostic findings in 16% (14/87) of the patients; in 34% (30/87) of the patients, Fludeoxyglucose F18 Injection PET images provided new findings. In 32% (27/87), imaging with Fludeoxyglucose F18 Injection was inconclusive. The impact of these imaging findings on clinical outcomes is not known. Several other studies comparing imaging with Fludeoxyglucose F18 Injection results to subsphenoidal EEG, MRI and/or surgical findings supported the concept that the degree of hypometabolism corresponds to areas of confirmed epileptogenic foci. The safety and effectiveness of Fludeoxyglucose F18 Injection to distinguish idiopathic epileptogenic foci from tumors or other brain lesions that may cause seizures have not been established.

Pediatric Use

8.4 Pediatric Use The safety and effectiveness of Fludeoxyglucose F18 Injection in pediatric patients with epilepsy is established on the basis of studies in adult and pediatric patients. In pediatric patients with epilepsy, the recommended dose is 2.6 mCi. The optimal dose adjustment on the basis of body size or weight has not been determined. In the oncology or cardiology settings, the safety and effectiveness of Fludeoxyglucose F18 Injection have not been established in pediatric patients.

Pregnancy

8.1 Pregnancy Risk Summary Data from published case series and case reports describe Fludeoxyglucose F 18 Injection crossing the placenta with uptake by the fetus ( see Data ). All radiopharmaceuticals have the potential to cause fetal harm depending on the fetal stage of development and the magnitude of the radiation dose. However, published studies that describe Fludeoxyglucose F 18 Injection use in pregnant women have not identified a risk of drug-associated major birth defects, miscarriage, or adverse maternal or fetal outcomes. If considering Fludeoxyglucose F 18 Injection administration to a pregnant woman, inform the patient about the potential for adverse pregnancy outcomes based on the radiation dose from Fludeoxyglucose F 18 Injection and the gestational timing of exposure. The estimated background risk of major birth defects and miscarriage for the indicated population is unknown. All pregnancies have a background risk of birth defect, loss, or other adverse outcomes. In the U.S. general population, the estimated background risk of major birth defects and miscarriage in clinically recognized pregnancies are 2-4% and 15-20%, respectively. Data Human Data Data from published case series and case reports describe Fludeoxyglucose F 18 Injection crossing the placental barrier and visualization of radioactivity throughout the body of the fetus. The estimated fetal absorbed radiation dose from the maximum labeled dose (370 MBq) of Fludeoxyglucose F 18 was 10mGy with first trimester exposure to PET alone and 20mGy with first trimester exposure to PET/CT scan combination. Long-term adverse radiation effects to a child exposed to Fludeoxyglucose F 18 Injection in utero are unknown. No adverse fetal effects or radiation-related risks have been identified for diagnostic procedures involving less than 50mGy, which represents less than 20mGy fetal doses.

Use In Specific Populations

8 USE IN SPECIFIC POPULATIONS • Lactation: Temporarily discontinue breastfeeding. A lactating woman should pump and discard breastmilk for 9 hours after Fludeoxyglucose F18 Injection ( 8.2 ). • Pediatric Use: Safety and effectiveness in pediatric patients have not been established in the oncology and cardiology settings ( 8.4 ). 8.1 Pregnancy Risk Summary Data from published case series and case reports describe Fludeoxyglucose F 18 Injection crossing the placenta with uptake by the fetus ( see Data ). All radiopharmaceuticals have the potential to cause fetal harm depending on the fetal stage of development and the magnitude of the radiation dose. However, published studies that describe Fludeoxyglucose F 18 Injection use in pregnant women have not identified a risk of drug-associated major birth defects, miscarriage, or adverse maternal or fetal outcomes. If considering Fludeoxyglucose F 18 Injection administration to a pregnant woman, inform the patient about the potential for adverse pregnancy outcomes based on the radiation dose from Fludeoxyglucose F 18 Injection and the gestational timing of exposure. The estimated background risk of major birth defects and miscarriage for the indicated population is unknown. All pregnancies have a background risk of birth defect, loss, or other adverse outcomes. In the U.S. general population, the estimated background risk of major birth defects and miscarriage in clinically recognized pregnancies are 2-4% and 15-20%, respectively. Data Human Data Data from published case series and case reports describe Fludeoxyglucose F 18 Injection crossing the placental barrier and visualization of radioactivity throughout the body of the fetus. The estimated fetal absorbed radiation dose from the maximum labeled dose (370 MBq) of Fludeoxyglucose F 18 was 10mGy with first trimester exposure to PET alone and 20mGy with first trimester exposure to PET/CT scan combination. Long-term adverse radiation effects to a child exposed to Fludeoxyglucose F 18 Injection in utero are unknown. No adverse fetal effects or radiation-related risks have been identified for diagnostic procedures involving less than 50mGy, which represents less than 20mGy fetal doses. 8.2 Lactation Risk Summary A published case report and case series show the presence of Fludeoxyglucose F 18 Injection in human milk following administration. There are no data on the effects of Fludeoxyglucose F 18 Injection on the breastfed infant or the effects on milk production. Exposure of Fludeoxyglucose F 18 Injection to a breastfed infant can be minimized by temporary discontinuation of breastfeeding ( see Clinical Considerations ). The developmental and health benefits of breastfeeding should be considered along with the mother’s clinical need for Fludeoxyglucose F 18 Injection, any potential adverse effects on the breastfed child from Fludeoxyglucose F 18 Injection or from the underlying maternal condition. Clinical Considerations To decrease radiation exposure to the breastfed infant, advise a lactating woman to pump and discard breastmilk and avoid close (breast) contact with the infant for at least 9 hours after the administration of Fludeoxyglucose F 18 Injection. 8.4 Pediatric Use The safety and effectiveness of Fludeoxyglucose F18 Injection in pediatric patients with epilepsy is established on the basis of studies in adult and pediatric patients. In pediatric patients with epilepsy, the recommended dose is 2.6 mCi. The optimal dose adjustment on the basis of body size or weight has not been determined. In the oncology or cardiology settings, the safety and effectiveness of Fludeoxyglucose F18 Injection have not been established in pediatric patients.

How Supplied

16 HOW SUPPLIED Fludeoxyglucose F18 Injection, USP is supplied in a multi-dose, capped 30 mL glass vial containing between 0.740 GBq/mL–11.1 GBq/mL (20 mCi/mL—300 mCi/mL), of no carrier added 2‑deoxy-2-[F 18] fluoro-D-glucose, at end of synthesis, in approximately 20 mL. The contents of each vial are sterile, pyrogen-free and preservative-free. NDC 73410-003-01 This radiopharmaceutical is licensed by the State of New York, Department Of Health, Bureau of Environmental Radiation Protection, for distribution to persons licensed pursuant to New York's Regulatory Code for Radioactive material specified in Chapter 1-‑Part 16 of the State Sanitary Code, as appropriate, or under equivalent licenses of an Agreement State or Licensing State. Storage Store the Fludeoxyglucose F18 Injection vial upright in a lead shielded container at 25°C (77°F); excursions permitted to 15-30°C (59-86°F). Store and dispose of Fludeoxyglucose F18 Injection in accordance with the regulations and a general license, or its equivalent, of an Agreement State or a Licensing State. The expiration date and time are provided on the container label. Use Fludeoxyglucose F18 Injection within 12 hours from the EOS time.

Learning Zones

The Learning Zones are an educational resource for healthcare professionals that provide medical information on the epidemiology, pathophysiology and burden of disease, as well as diagnostic techniques and treatment regimens.

Disclaimer

The drug Prescribing Information (PI), including indications, contra-indications, interactions, etc, has been developed using the U.S. Food & Drug Administration (FDA) as a source (www.fda.gov).

Medthority offers the whole library of PI documents from the FDA. Medthority will not be held liable for explicit or implicit errors, or missing data.

Drugs appearing in this section are approved by the FDA. For regions outside of the United States, this content is for informational purposes only and may not be aligned with local regulatory approvals or guidance.