Data from FDA - Curated by EPG Health - Last updated 27 July 2017

Indication(s)

INDICATIONS AND USAGE Tc99m Sulfur Colloid is used in lymphoscintigraphy studies in breast cancer patients, for liver, spleen and bone marrow imaging and gastric transit studies and gastroesophageal reflux.

Learning Zones

An epgonline.org Learning Zone (LZ) is an area of the site dedicated to providing detailed self-directed medical education about a disease, condition or procedure.

Acute and Advanced Heart Failure

Acute and Advanced Heart Failure

What are the most effective treatments for acute heart failure? Can you define advanced heart failure? Discover here...

+ 3 more

Allergic Rhinitis

Allergic Rhinitis

Allergic rhinitis causes great strain on the workforce. Help to reduce sick days and improve productivity with appropriate treatment options.

+ 4 more

Anticoagulation Therapy for Stroke Prevention

Anticoagulation Therapy for Stroke Prevention

Anticoagulation therapy for Stroke Prevention Learning Zone offers a deep-dive into atrial fibrillation causes, consequences, diagnosis and management to help you deliver optimal care and prevent strokes in patients living with this common arrhythmia.

Load more

Related Content

Usage information

Dosing and administration
INSTRUCTIONS Preparation of Technetium Tc 99m-Sulfur Colloid: Collect components: 10 ml. Reaction Vial, Solution A, Solution B, Lead Pig, Boiling Water Bath. Draw up 1 ml. Solution A. (HCl solution) in syringe. Draw up 2.5 ml. Tc-99m Pertechnetate containing desired activity, dilute with sterile normal saline if necessary. Add the 2.5 ml Tc-99m Pertechnetate to the shielded reaction vial. Immediately add the 1 ml. Solution A. Vent vial to release excess vacuum. Remove vent before boiling. Shake gently to mix. Place shielded vial in boiling water bath for 5 minutes for liver imaging and 3 minutes for lymphoscintigraphy imaging use. Remove from boiling water and let cool for a few minutes. Draw up 1 ml. Solution B. (Phosphate Buffer) while reaction vial is cooling After cooling Reaction vial, add the 1 ml Solution B and shake gently to mix. Caution: be sure vial is cool to avoid excess pressure Quality control: ITLC-SG in normal saline. Greater than 95% should stay at the origin Tc 99m Sulfur Colloid expires 6 hours after mixing

More information

Category Value
Agency product number 2G86QN327L
Orphan designation No
Product NDC 51808-220
Date Last Revised 01-07-2012
Type HUMAN PRESCRIPTION DRUG
Marketing authorisation holder AnazaoHealth Corporation